尚杰,董敏,任耘.无针注射器和胰岛素笔注射胰岛素降糖疗效和安全性的Meta分析[J].中国药事,2019,33(8):919-928
无针注射器和胰岛素笔注射胰岛素降糖疗效和安全性的Meta分析
Meta-Analysis of the Efficacy and Safety of Needle-free Syringes and Insulin Pens for Insulin Injection to Treat Diabetes Mellitus
投稿时间:2019-04-15  
DOI:10.16153/j.1002-7777.2019.08.012
中文关键词: 胰岛素  无针注射器  胰岛素笔  喷射式注射器  糖尿病  Meta分析
英文关键词: insulin  needle-free syringe  insulin pen  jet syringe  diabetes mellitus  Meta analysis
基金项目:
作者单位E-mail
尚杰 天津医科大学总医院, 天津 300052  
董敏 天津医科大学总医院, 天津 300052  
任耘 天津医科大学总医院, 天津 300052 pharmary@sina.com 
摘要点击次数: 1398
全文下载次数: 718
中文摘要:
      目的:系统评估应用无针注射器与胰岛素笔注射胰岛素降糖的疗效和安全性。方法:按照纳入和排除标准,计算机检索无针注射器与胰岛素笔的前瞻性队列研究文献。对所纳入文献进行质量评价及提取资料后,采用Rev Man 5.3软件进行Meta分析。结果:根据纳入排除标准共纳入8篇符合标准的文献,包括466例患者,8项研究NOS评分均大于8分。Meta分析的结果表明,在降低HbA1c水平方面无针注射器组优于胰岛素笔组[MD=-1.05,95% CI(-1.88,-0.22),P=0.01];在降低FBG、早餐后2 h BG和2 h PG方面,无针注射器组显著优于胰岛素笔组[MD=-1.37,95% CI(-1.82,-0.92),P<0.00001;MD=-1.14,95% CI(-1.49,-0.78),P<0.00001;MD=-2.26,95% CI(-3.04,-1.48),P<0.000 01]。在安全性方面,低血糖发生率、注射后疼痛和出血/瘀斑发生率,无针注射器组和胰岛素笔组比较差异无统计学意义[RR=0.30,95% CI(0.08,1.06),P=0.06;RR=0.33,95% CI(0.07,1.58),P=0.17;RR=0.39,95% CI(0.01,19.86),P=0.64],但注射后发生红肿硬结的发生率,无针注射器组少于胰岛素笔组[RR=0.26,95% CI(0.08,0.82),P=0.02]。结论:用无针注射器注射胰岛素可以提高疗效,减少红肿硬结的发生。
英文摘要:
      Objective:To systematically evaluate the efficacy and safety of needle-free syringes and insulin pens for insulin injection to treat diabetes mellitus. Methods:According to inclusion and exclusion criteria, prospective cohort studies of needle-free syringes and insulin pens were retrieved by computer. After the quality of the included literature was evaluated and extracted, meta-analysis was carried out by using Rev Man 5.3. Results:A total of 8 eligible articles were included according to the inclusion and exclusion criteria, covering 466 patients and 8 studies with NOS scores greater than 8 points. The results of the meta-analysis showed that the needle-free syringe group was superior to the insulin pen group in reducing HbA1c levels[MD=-1.05, 95% CI (-1.88, -0.22), P=0.01]. The needle-free syringe group was superior to the insulin pen group in reducing the FBG, 2h BG after breakfast and 2h PG[MD=-1.37, 95% CI (-1.82, -0.92), P<0.00001; MD=-1.14, 95% CI (-1.49,-0.78), P<0.00001; MD=-2.26, 95% CI (-3.04, -1.48), P<0.00001]. In terms of safety, there was no significant difference in the incidence of hypoglycemia, post-injection pain, and bleeding/ecchymosis between the needle-free syringe group and the insulin pen group[RR=0.30, 95% CI (0.08, 1.06), P=0.06; RR=0.33, 95% CI (0.07, 1.58), P=0.17; RR=0.39, 95% CI (0.01, 19.86), P=0.64], but the incidence of redness and induration after injection of the needle-free syringe group was less than that of the insulin pen group[RR=0.26, 95% CI (0.08, 0.82), P=0.02]. Conclusion:Injection of insulin with a needle-free syringe can improve the efficacy and reduce the incidence of redness and induration.
查看全文   查看/发表评论  下载PDF阅读器
关闭